Refrigerant Pipe Compressor to Condenser
Operation number: 87465-2
Refrigerant pipe compressor to condenser
Note! Some variation in the illustrations may occur, but the essential information is always correct.
Removal
Note! Removal steps in this procedure may contain installation details.
Warning! Follow the safety instructions for work on the air conditioning system. Refer to: Refrigerant, safety regulations Refrigerant, Safety Regulations.
Note! First read the instructions covering slow and fast leaks. Refer to: Oil air conditioning (A/C) system, filling Oil Air Conditioning (A/C) System, Filling.
Drain the refrigerant from the air conditioning system. Refer to: Refrigerant, draining Refrigerant, Draining.
Torque: M8, 24 Nm
Torque: M8, 24 Nm
Installation
To install, reverse the removal procedure
Vacuum pump the AC system. Refer to: Vacuum pumping Vacuum Pumping.
Fill the AC-system with refrigerant. Refer to: Refrigerant, filling Refrigerant, Filling.
Leak-trace the air conditioning system. Refer to: Leak tracing, fluorescent tracing agent / UV lamp Leak Tracing, Fluorescent Tracing Agent/UV Lamp
Or Leak tracing, fluorescent tracing agent / UV lamp Leak Tracing, Fluorescent Tracing Agent/UV Lamp.
Carry out a performance test on the climate control system. Refer to: Climate system, performance test Climate System, Performance Test.