Fault-Tracing Information
Fault-tracing
Checking the wiring and terminals
- Ignition off, wait for 15 seconds.
- Disconnect the connector to the roof lighting control unit.
- Disconnect the connector for Supplemental restraint system module (SRS).
Check connectors for damage to pins and connections.
Check the connectors. Check for loose connections. Check for contact resistance. Check for oxidation.
Also check the other connectors and terminals that join the cable between the supplemental restraint system module (SRS) and the roof lighting control unit.
Check the cable. Check for an open-circuit. Check for a short-circuit to supply voltage.
Take readings between:
- Supplemental restraint system module (SRS) terminal #C2:70(#A45) and the connector for the roof lighting control unit terminal #C1:7.
- Roof lighting control unit terminal #C1:4 and ground terminal.
Remedy as necessary.
Other information
- Connecting the breakout box Connecting the Breakout Box, Supplemental Restraint System Module (SRS)
- For further information, see the wiring diagram.
- Lighting, internal front Front Interior Lighting
- Cable harness SRS system, repair Cable Harness SRS System, Repair
- Checking wiring and terminals Checking Wiring and Terminals
Continue - Verification
-------------------------------------------------
Fault-tracing information
Attempt New Test - Checking the wiring and terminals
-------------------------------------------------
Verification
Verification
Hint: After carrying out the repair check that the fault has been remedied.
- Reinstall the connectors, components etc.
- Switch on the ignition. Wait 10 seconds.
Read diagnostic trouble codes by clicking the VCT2000 symbol.
If the fault is intermittent, the fault has been remedied.
Is the fault intermittent?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFICATION FAILED - Fault-tracing information
VERIFIED - VERIFIED
-------------------------------------------------