Description of Parameters
Description of parameters
Parameters, status
Switch, memory 1
Readout as to whether the control module reads the status of the memory 1 switch as depressed.
Switch, memory 2
Readout as to whether the control module reads the status of the memory 2 switch as depressed.
Switch, memory 3
Readout as to whether the control module reads the status of the memory 3 switch as depressed.
Switch, memory
Readout as to whether the control module reads the status of the programming button (MEM) as depressed.
Switch, displacement motor, forward
Readout as to whether the control module reads the status of the control as active or inactive.
Switch, displacement motor, rearward
Readout as to whether the control module reads the status of the control as active or inactive.
Switch, inclination motor, forward
Readout as to whether the control module reads the status of the control as active or inactive.
Switch, inclination motor, rearward
Readout as to whether the control module reads the status of the control as active or inactive.
Switch, seat height motor, up
Readout as to whether the control module reads the status of the control as active or inactive.
Switch, seat height motor, down
Readout as to whether the control module reads the status of the control as active or inactive.
Switch, tilt motor, up
Readout as to whether the control module reads the status of the control as active or inactive.
Switch, tilt motor, down
Readout as to whether the control module reads the status of the control as active or inactive.
Displacement motor, forward
Readout as to whether the control module reads the status of the motor as on or off.
Displacement motor, rearward
Readout as to whether the control module reads the status of the motor as on or off.
Inclination motor, forward
Readout as to whether the control module reads the status of the motor as on or off.
Inclination motor, rearward
Readout as to whether the control module reads the status of the motor as on or off.
Seat height motor, up
Readout as to whether the control module reads the status of the motor as on or off.
Seat height motor, down
Readout as to whether the control module reads the status of the motor as on or off.
Tilt motor, up
Readout as to whether the control module reads the status of the motor as on or off.
Tilt motor, down
Readout as to whether the control module reads the status of the motor as on or off.
Parameters, value
ECU power supply
Readout of power supply to power seat module (PSM).
Position, displacement motor
The Hall sensor detects current seat position. When the displacement motor operates the control module counts the number of pulses from the Hall sensor.
Readout of seat position as indicated by number of pulses.
Measurement range -32768 - 32767 pulses.
Position, inclination motor
The Hall sensor detects current seat position. When the inclination motor operates the control module counts the number of pulses from the Hall sensor.
Readout of seat position as indicated by number of pulses.
Measurement range -32768 - 32767 pulses.
Position sensor, seat height motor
The Hall sensor detects current seat position. When the seat height motor operates the control module counts the number of pulses from the Hall sensor.
Readout of seat position as indicated by number of pulses.
Measurement range -32768 - 32767 pulses.
Position, tilt motor
The Hall sensor detects current seat position. When the seat height motor operates the control module counts the number of pulses from the Hall sensor.
Readout of seat position as indicated by number of pulses.
Measurement range -32768 - 32767 pulses.