For Connection of Breakout Box to Central Electronic Module (CEM)
Connecting the breakout box
Special tools:
951 2979 CEM adapter 951 2979 CEM Adapter
951 1428 Breakout box 951 1428 Breakout Box
Caution! Avoid touching control module connector pins and corresponding cable harness connectors. There is a risk of electrostatic discharge, which could damage the control module. Relieve any charge on yourself and the tools to be used by holding the metal part of the tool and touching part of the body just before starting work.
General information
Visually check the connectors to ensure that the male and female terminals are not damaged and that the cables for the female halves are properly connected.
The breakout box is designed to facilitate reading off control module output and input signals when the control module is connected as well as resistance of cables and components when the control module is disconnected. Using a breakout box reduces the risk of unintentionally short-circuiting cables or damaging connector pins.
Connecting the breakout box
- Ignition off
- Expose the connectors for the central electronic module (CEM).
Connect breakout box 951 1428 Breakout box 951 1428 Breakout Box to the adapter.
Central Electronic Module (CEM)
- Connect adapter to the control module connectors C1, C2, C3 and C4.
- For connector C1, terminals #C1:1 - #C1:60 correspond to terminals #A1-#A60 on the breakout box.
#C1:61 - #C1:76 correspond to #B1 - #B16 on the breakout box.
- For connector C2, terminals #C2:1 - #C2:60 correspond to terminals #C1 - #C60 on the breakout box.
#C2:61 - #C2:76 correspond to #D1 - #D16 on the breakout box.
- For connector C3, terminals #C3:1 - #C3:60 correspond to terminals #E1-#E60 on the breakout box.
#C3:61 - #C3:76 correspond to #F1 - #F16 on the breakout box.
- For connector C4, terminals #C4:1 - #C4:20 correspond to terminals #B21 - #B40 on the breakout box.