Short-Circuit to Ground
Short-circuit to ground
Checking for a short-circuit
If the fault is intermittent, it has been registered previously but is no longer present. Intermittent faults can occur for a number of different reasons. The fault is evaluated depending on how it occurs.
Check the signal cable from control module terminal #B8 (#28) to the power mirror. Check for a short-circuit to ground.
Replace the signal cable if a fault is found.
Try replacing the power door mirror if no fault is found.
Remedy as necessary.
Other information:
- Rear view mirror external Rear View Mirror External
- Signal specification Signal Specification, Driver's Door Module / Passenger Door Module (DDM/PDM)
- Checking wiring and terminals Checking Wiring and Terminals
Continue - Verification
-------------------------------------------------
Verification
Verifying door mirror
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on.
Check that the door mirrors can be operated.
Do the controls for the power door mirror function?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFIED - FAULT FOUND
VERIFICATION FAILED - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Attempt New Test - Checking for a short-circuit
-------------------------------------------------