Signal Too Low
Signal too low
Checking the component and wiring
Check the signal cable for the alarm output S1. Check between accessory electronic module (AEM) terminal #B34 and the connector for the alarm unit. Check for a short-circuit to ground.
Remedy as necessary.
Other information:
- Connecting the breakout box Connecting the Breakout Box, Accessory Electronic Module (AEM)
- Accessory control module (AEM) Accessory Electronic Module (AEM), Replacing
- Signal specification Signal Specification, Accessory Electronic Module (AEM)
- Checking wiring and terminals Checking Wiring and Terminals
Continue - Verification
-------------------------------------------------
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reconnect the components, connectors etc.
- Ignition on.
Check the function of the alarm by activating it appropriately.
Does the system function?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFIED - FAULT FOUND
VERIFICATION FAILED - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Attempt New Test - Checking the component and wiring
-------------------------------------------------