FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Part 3






Inflatable curtain (IC), destruction

Special tools:
951 2944 Disarm. equipm.for Suppl.Restraint Syst. 951 2944 Disarm. Equipm. For Suppl. Restraint Syst.

Note! Only applies to S40 (04-) and V50

Preparatory work

Installation of inflatable curtain (IC) in mounting fixture





Warning! Use personal protection equipment. See Discarding pyrotechnic components Discarding Pyrotechnic Components.

Install the gas generator without inflatable curtain in its normal screw joint on the mounting bracket.

Note! Direct the inflatable curtain component away from the user and make sure it extends away from the gas generator.

Screw the mounting bracket to the fixture.

Destruction of inflatable curtain (IC)

Connecting cables to the inflatable curtain (IC)




Remove the key from the discharge box and store so that it is inaccessible for unauthorised use.
Select the correct adapter cable for the gas generator.
Connect the adapter cable to the inflatable curtain. Check that it is properly connected.

Warning! Remove all loose objects on, or directly connected to, the gas generator.

Lay out the connection cable so that the user is 9 m from the inflatable curtain.
Connect the adapter cable to the connection cable and fully extend the leads.
Connect the cable to the discharge box.
Connect the discharge box to a fully charged 12 V battery.

Destruction of inflatable curtain (IC)




Insert the key and turn it to position 1.
Destroy the gas generator by connecting the rocker switch and pushbutton.
Turn the key to position 0.
Remove the key from the discharge box and store so that it is inaccessible for unauthorised use.

Warning! Use pliers when removing due to heat development.

If the adapter cable is still attached, detach the adapter cable from the gas generator as soon as possible after destruction. Use protective safety gloves.
Remove the destroyed gas generator from the fixture.

Inflatable curtain (DMIC), destruction

Special tools:
951 2944 Disarm. equipm.for Suppl.Restraint Syst. 951 2944 Disarm. Equipm. For Suppl. Restraint Syst.

Note! Only applies to C70 (06-)

Preparatory work

Installation of inflatable curtain (DMIC) in mounting fixture





Warning! Use personal protection equipment. See Discarding pyrotechnic components Discarding Pyrotechnic Components.

Install the gas generator with the inflatable curtain in its normal screw joint on the mounting bracket.

Note! Direct the inflatable curtain component away from the user and make sure it extends away from the gas generator.

Screw the mounting bracket to the fixture.

Connecting cables to the inflatable curtain (DMIC)




Remove the key from the discharge box and store so that it is inaccessible for unauthorised use.
Select the correct adapter cable for the gas generator.
Connect the adapter cable to the inflatable curtain. Check that it is properly connected.

Warning! Remove all loose objects on, or directly connected to, the gas generator.

Lay out the connection cable so that the user is nine metres from the inflatable curtain.
Connect the adapter cable to the connection cable and fully extend the leads.
Connect the cable to the discharge box.
Connect the discharge box to a fully charged 12 V battery.





Insert the key and turn it to position 1.
Destroy the gas generator by connecting the rocker switch and pushbutton.
Turn the key to position 0.
Remove the key from the discharge box and store so that it is inaccessible for unauthorised use.

Warning! Use pliers when removing due to heat development.

If the adapter cable is still attached, detach the adapter cable from the gas generator as soon as possible after destruction. Use protective safety gloves.
Remove the destroyed gas generator from the fixture.

Roll bar (ROPS), destruction

Special tools:
951 2944 Disarm. equipm.for Suppl.Restraint Syst. 951 2944 Disarm. Equipm. For Suppl. Restraint Syst.

Preparatory work

Installation of roll bar (ROPS) in mounting fixture





Note! Only applies to C70 (06-)

Warning! Use personal protection equipment in accordance with: Discarding pyrotechnic components Discarding Pyrotechnic Components.

Install the roll bar (ROPS) in its normal screw joint on the mounting bracket.

Connecting cables to the roll bar (ROPS)




Remove the key from the discharge box and store so that it is inaccessible for unauthorised use.
Select the correct adapter cable for the gas generator.
Connect the adapter cable to the roll bar (ROPS) gas generator. Check that it is properly connected.

Warning! Remove all loose objects on, or directly connected to, the gas generator.

Lay out the connection cable so that the user is 9 m from the roll bar (ROPS).
Connect the adapter cable to the connection cable and fully extend the leads.
Connect the cable to the discharge box.
Connect the discharge box to a fully charged 12 V battery.





Insert the key and turn it to position 1.
Destroy the roll bar (ROPS) gas generator by connecting the rocker switch and pushbutton.
Turn the key to position 0.
Remove the key from the discharge box and store so that it is inaccessible for unauthorised use.

Warning! Use pliers when removing due to heat development.

If the adapter cable is still attached, detach the adapter cable from the gas generator as soon as possible after destruction. Use protective safety gloves.
Remove the destroyed roll bar (ROPS) from the fixture.