Fault-Tracing Information






Fault-tracing

Checking the wiring and component
Power Operated Tailgate Module (POT) controls the hydraulic operation of the tailgate. If the hydraulic pump does not work this indicates open circuit, short-circuiting to ground/voltage, relay problem in module or that the pump has failed.
Check the cables for open circuit and short-circuiting to ground/voltage.
If the leads are intact, replace Power Operated Tailgate Module (POT) and its hydraulic parts.
Remedy as necessary.

Other information
- Location of components Locations
- Power Liftgate Module Service and Repair
- Load sensor, tailgate Load Sensor, Tailgate
- Luggage Compartment Lid Lift Cylinder Service and Repair

Has Power Operated Tailgate Module (POT) been replaced?

Yes - Initiation of tailgate's position

No - Verification

-------------------------------------------------

Verification




Verification





Hint: After carrying out the repair check that the fault has been remedied.

- Ignition off.
- Reinstall the connectors, components etc.
- Ignition on.
- Check the function by opening and closing the tailgate using the different button combinations.
- Read off the diagnostic trouble codes (DTCs) by clicking on the VCT2000 symbol.
- Check that the diagnostic trouble code has disappeared or changed status to intermittent. Then the problem has been solved.





Has the fault been remedied?

Yes - FAULT FOUND

No - Attempt New Test

------------------------

Attempt New Test - Information

-------------------------------------------------

Information

Attempt New Test - Checking the wiring and component

-------------------------------------------------

Initiation of tailgate's position





Initiation of tailgate's position, Power Operated Tailgate Module (POT)

Initiation of tailgate's position
After changing Power Operated Tailgate Module (POT) the tailgate's position must be initiated in the software.

Carry out as follows:

- Load new software into the control module.
- Click the VCT2000 symbol and follow the instructions there.









DONE

------------------------

DONE - Verification

-------------------------------------------------