Service Port HVAC: Service and Repair
Needle Valve
Operation number: 87417-2
NOTE: Some variation in the illustrations may occur, but the essential information is always correct.
Removal
NOTE: Removal steps in this procedure may contain installation details.
Drain the refrigerant from the system.
Special Tool: 951 1204
Installation
Use: 981 1994.
Torque: Needle valve, 6 Nm
Vacuum pump the air conditioning system.
Fill the air conditioning system with refrigerant.
Leak-trace the air conditioning system.
Carry out a performance test on the climate control system.