Checking Ground Lead to Control Panel
Fault-Tracing Information
Condition
Possible source
- Open-circuit
- Short-circuit to ground
- Short-circuit to supply voltage.
Fault symptom[s]
- Automatic seat operation does not function.
Checking Ground Lead To Control Panel
Checking ground leads to the control panel
HINT: None of the control buttons work if there is an open-circuit in the cable.
Check the cable between connector C terminal #6 and ground and terminal #7 and ground. Check for an open-circuit. See Checking wiring and terminals. Permanent fault:Open-circuit, permanent faults. Check for a short-circuit to supply voltage. See Checking wiring and terminals. Permanent fault: Short-circuit to supply voltage. Permanent faults.
Remedy as necessary.
If no fault is found in the wiring replace control panel.