Service Port HVAC: Service and Repair
Needle Valve
Special tools:
951 1204
981 1994
NOTE: The illustrations in this service information are used for different model years and/or models. Some variation may occur. However, the essential information in the illustrations is always correct.
Preparatory work
Draining refrigerant
Drain the refrigerant from the system. See Refrigerant, draining.
Removal
Removing the needle valve / service valve
Remove the needle valve in the service valve. Use: 951 1204.
Installation
Installing the needle valve / service valve
Install the needle valve. Use: 951 1204.
Use: 981 1994 and Tighten, see: Specifications 108097493>.
NOTE: Use only your finger and thumb when tightening the needle valve to avoid damage to the valve seal.
Finishing
Checking the function and leak tracing
Vacuum pump the air conditioning (A/C) system. See: Vacuum pumping.
Fill the air conditioning (A/C) system with refrigerant. See: Refrigerant, filling.
Leak trace the air conditioning (A/C) system. See: Leak detection, tracer agent or: Leak tracing, electronic leak tracer.
Checking the performance
Carry out a performance test on the climate control unit. See: Climate control system, check.