Signal Too High/Signal Too Low
Signal too high/signal too low
Checking diagnostic trouble codes (DTCs)
If the malfunction is intermittent, it means that the malfunction has been registered at an earlier time but the malfunction no longer remains. Intermittent faults can occur for a number of different reasons. The fault is evaluated depending on how it occurs.
Check if the fault is permanent or intermittent.
Click on the VCT2000 symbol to read off the diagnostic trouble codes (DTCs).
Is the fault intermittent?
Yes - Troubleshooting procedure complete
No - Checking the wiring and sensors
-------------------------------------------------
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off.
- Reinstall the connectors, components etc.
- Ignition on.
Check that the control of the roof is working in both directions.
Does operation of the roof work?
Yes - FAULT FOUND
No - Fault-tracing information
-------------------------------------------------
Fault-tracing information
The fault must be diagnosed and remedied. As this is not the case, the fault-tracing has failed.
Exit fault-tracing or try again.
Do you want to exit fault-tracing?
Yes - Exit Fault-tracing
No - Checking diagnostic trouble codes (DTCs)
-------------------------------------------------
Checking the wiring and sensors
Check the cables between the hydraulic pump's valves and Convertible Roof Module (CRM).
Note! Only check the cables for the hydraulic valve in question.
Valve 1
Check the cables for short-circuit to voltage, short-circuit to ground and open circuit.
Take readings between:
- Convertible Roof Module (CRM) terminal #C2 (#A12) and valve 1.
- Convertible Roof Module (CRM) terminal #C8 (#A18) and valve 1.
Valve 2
Check the cables for short-circuit to voltage, short-circuit to ground and open circuit.
Take readings between:
- Convertible Roof Module (CRM) terminal #C3 (#A13) and valve 2.
- Convertible Roof Module (CRM) terminal #C9 (#A19) and valve 2.
Valve 3
Check the cables for short-circuit to voltage, short-circuit to ground and open circuit.
Take readings between:
- Convertible Roof Module (CRM) terminal #C4 (#A14) and valve 3.
- Convertible Roof Module (CRM) terminal #C10 (#A20) and valve 3.
Valve 4
Check the cables for short-circuit to voltage, short-circuit to ground and open circuit.
Take readings between:
- Convertible Roof Module (CRM) terminal #C5 (#A15) and valve 4.
- Convertible Roof Module (CRM) terminal #C11 (#A21) and valve 4.
Replace the signal cable if a fault is found.
If no malfunctions were detected when checking the signal cable, try replacing hydraulic pump.
Remedy as necessary.
Other information
- Signal specification Signal Specification, Convertible Roof Module (CRM)
- For information about the cable routing, see the relevant Wiring Diagram.
- Checking wiring and terminals Checking Wiring and Terminals
- Covertible Top Position Switch Covertible Top Position Switch
- Hydraulic pump Service and Repair Hydraulic pump Service and Repair
Was a fault detected?
Yes - Verification
No - Replacing the control module
-------------------------------------------------
Replacing the control module
If the fault is not found when checking the signal cable and Hall sensor, it is probably an internal fault in the convertible roof module (CRM).
- Ignition off. Wait 1 minute.
- Cut off voltage feed to Convertible Roof Module (CRM) by removing the battery's plus cable.
Replace Convertible Roof Module (CRM).
Other information
- Signal specification Signal Specification, Convertible Roof Module (CRM)
- For information about the cable routing, see the relevant Wiring Diagram.
- Convertible Roof Module (CRM) Removal and Replacement
Continue - Verification
-------------------------------------------------