R.H.D
Over heated
Checking the status
- Ignition on.
Click the VCT2000 symbol to activate the blower fan 100 %.
Check if the fault is permanent or intermittent.
The fault is permanent if the blower fan does not activate.
If the blower fan is activated, this is an indication that the fault was present previously but that it is not active at the moment, i.e. the fault is intermittent.
Continue - Checking the component and wiring
-------------------------------------------------
Checking the component and wiring
Check the voltage supply level to the blower fan.
Take readings between:
- Blower fan connector terminal #1 and ground.
If the voltage exceeds 19 volts, the blower fan stops.
Remedy as necessary.
Other information
- Connecting the breakout box Connecting the Breakout Box, Central Electronic Module (CEM)
- Signal specification Signal Description, Central Electronic Module (CEM)
- Control module relay box passenger compartment Service and Repair
- Blower motor passenger compartment, R.H.D Blower Motor Passenger Compartment
- Checking wiring and terminals Checking Wiring and Terminals
Was a fault detected?
Yes - Verification
No - Signal too high
-------------------------------------------------
Signal too high
Signal too high
Checking the wiring
- Ignition off
- Connect the breakout box to the central electronic module (CEM)
- Start the engine.
Check the 30-supply to central electronic module (CEM) terminal #E27 (#27) and #D10 (#10). The voltage must not exceed 15 volts at 2,000 rpm.
Also check that the battery is not over-charging.
Remedy as necessary.
Other information
- Connecting the breakout box Connecting the Breakout Box, Central Electronic Module (CEM)
- Signal specification Signal Description, Central Electronic Module (CEM)
- Location of components Component Location, Central Electronic Module (CEM)
- Control module relay box passenger compartment Service and Repair
- Checking wiring and terminals Checking Wiring and Terminals
Continue - Verification
------------------------
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Start the engine.
Read off the 30-supply by clicking the VCT2000 symbol.
Check whether the value is within the permitted range, the normal value when the generator is loading: 13.0-14.5 V.
Is the value OK?
Yes - Troubleshooting procedure complete
No - Fault-tracing information
-------------------------------------------------
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on.
Activate the blower fan.
Check that the function is OK.
Is the function OK?
Yes - Troubleshooting procedure complete
No - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit Fault-Tracing
No - Attempt New Test
-------------------------------------------------