Checking Local Lighting
Checking local lighting
Checking the connectors
- Ignition off
- Check the power door mirror connector. Check for contact resistance and oxidation.
In particular, check for any damage
- Ignition on.
Other information:
- To access the power door mirror connector, see Outside temperature sensor door mirror, replacing Service and Repair
- Checking wiring and terminals Checking Wiring And Terminals
Is the lamp in the power door mirror working?
Yes - FAULT FOUND
No - Checking the components and wiring
-------------------------------------------------
Checking the components and wiring
Check the cable between door control module terminal #10B and power door mirror terminal #6. Check for an open-circuit. Check for a short-circuit to supply voltage.
Check the cable between door control module terminal #8B and power door mirror terminal #13 for an open-circuit.
Remedy as necessary.
Other information:
- Signal specification Signal Specification, Driver Door Module (DDM) / Passenger Door Module (PDM)
- Connecting the breakout box Connecting the Breakout Box
- To access the power door mirror connector, see Outside temperature sensor door mirror, replacing Service and Repair
- Bulb ground lighting door mirror, replacing Bulb Ground Lighting Door Mirror, Replacing
- Checking wiring and terminals Checking Wiring And Terminals
Continue - Verification
-------------------------------------------------
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on.
Check if the lamp in the power door mirror lights.
Is the bulb in the power door mirror working?
Yes - Verification complete
No - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit Fault-Tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking the connectors
-------------------------------------------------