Activating Components / Functions, Combustion Preheater Module (CPM)






Activating components and functions

Checking the engine version
Is the fault-tracing being performed on a vehicle with a gasoline or a diesel engine?
1. Gasoline
2. Diesel.

Select the correct engine variant.

1 - additional heater

2 - additional heater

-------------------------------------------------

Activating components and functions, additional heater




- Ignition on.

Warning! When replacing the fuel line, the line must be filled with new fuel. For diesel engines, filling with fuel must not take more than a maximum of 8 minutes. When the heater is started, the fuel fills in approximately 2 minutes. However as the control module only permits 3 failed start attempts, it will be insufficient to start the heater.

Warning! If the fuel pump (FP) is activated for an excessive amount of time, smoke may be generated or the heater may be damaged.

Caution! The button for ending activation does not function on the heater and fuel pump (FP). To switch off, select an alternative in the drop down menu that will disable the function.

Activate components and/or functions by clicking the VCT2000 symbol.
The water pump, combustion fan, glow plugs, heater and fuel pump (FP) can be activated.
The parameters from the left-hand drop down box menus can also be read. Select an alternative from each drop down menu to be presented. Use the button to start the read off.
Activating components/functions Activating Components/Functions

Caution! In order for to enable start of the heater itself, the battery voltage must be normal, coolant temperature must be lower than +96 °C and the heater's after-run/stop sequence must be finished. There must also be enough fuel in the tank.

Caution! If the heater or other components are not activated, try closing down the activation window and then starting the activation again with the symbol for VCT2000.





Continue - DONE

-------------------------------------------------

Activating components and functions, additional heater




- Ignition on.

Warning! When replacing the fuel line, the line must be filled with new fuel. For gasoline engines, filling with fuel must not take more than a maximum of 10 minutes. When the heater is started, the fuel fills in approximately 2 minutes. However as the control module only permits 3 failed start attempts, it will be insufficient to start the heater.

Warning! If the fuel pump (FP) is activated for an excessive amount of time, smoke may be generated or the heater may be damaged.

Caution! The button for ending activation does not function on the heater and fuel pump (FP). To switch off, select an alternative in the drop down menu that will disable the function.

Activate components and/or functions by clicking the VCT2000 symbol.
The water pump, combustion fan, glow plugs, heater and fuel pump (FP) can be activated.
The parameters from the left-hand drop down box menus can also be read. Select an alternative from each drop down menu to be presented. Use the button to start the read off.
Activating components/functions Activating Components/Functions

Caution! In order for to enable start of the heater itself, the battery voltage must be normal, coolant temperature must be lower than +96 °C and the heater's after-run/stop sequence must be finished. There must also be enough fuel in the tank.

Caution! If the heater or other components are not activated, try closing down the activation window and then starting the activation again with the symbol for VCT2000.





Continue - DONE

-------------------------------------------------