Signal Missing. Intermittent Fault
Signal missing. Intermittent fault
Intermittent fault
- Ignition off.
Check the cable between control module terminal 51 (#A51) and transmission connector (control module side) terminal T #A17 for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Check the wiring between control module terminal 53 (#A53) and transmission connector #E (#A5) for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box, 4T65EV-GT Connecting the Breakout Box.
- To connect the breakout box to the transmission connector, see Connecting the breakout box, GM automatic transmissions, 4T65EV-GT Connecting the Breakout Box, GM Automatic Transmissions.
- For information about signals, see Signal specification, 4T65EV-GT Signal Specification.
Select Continue when the fault has been remedied.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Exit fault-tracing
------------------------
Attempt New Test - Intermittent fault
-------------------------------------------------