Faulty Signal
Faulty signal
Checking the status
If the fault is intermittent, it has been registered previously but is no longer present. Intermittent faults may be due to interference at start up of the control module or may be a different type of fault which occurs on different occasions. The fault is evaluated depending on how it occurs.
Replace the fuel level sensor if the fault is permanent.
Continue - Replacing the component
-------------------------------------------------
Replacing the component
Replace the fuel level sensor.
Other information:
Continue - Verification
-------------------------------------------------
Verification
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on.
Fill up with gas. Check that the level of the fuel gauge changes.
Is the value within its permitted range?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFIED - Fault Found
VERIFICATION FAILED - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - FAULT-TRACING FAILED
Attempt New Test - Checking the status
-------------------------------------------------