FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Signal Missing






Signal missing

Checking components and wiring

Caution! Do not apply rust solvent spray or grease to the heated oxygen sensor (HO2S) connector.

- Check the heated oxygen sensor (HO2S) connector. Check for contact resistance and oxidation.
Check the cable for calibration current between engine control module (ECM) terminal #A28 (#A28) and heated oxygen sensor (HO2S) terminal #2.
Check the cable for pump current between heated oxygen sensor (HO2S) terminal #6 and engine control module (ECM) terminal #A24 (#A24). Check for a short-circuit to each other.
Check the cable for an open-circuit.
Check between:
- Heated oxygen sensor (HO2S) terminal #5 and engine control module (ECM) terminal #A42 (#A42)
- Heated oxygen sensor (HO2S) terminal #2 and engine control module (ECM) terminal #A28 (#A28).
Remedy as necessary.

Other information
- Connecting the breakout box, B5244T5, B5254T2 Connecting the Breakout Box
- For information about signals for 5 cylinder engines: Signal specification Signal Description / Specification
- For information about signals for 6 cylinder engines: Signal specification Signal Description / Specification
- Heated oxygen sensor (HO2S), replacing Heated Oxygen Sensor (HO2S), Replacing
- Checking wiring and terminals Checking Wiring And Terminals














Continue - Verification

-------------------------------------------------

Verification




Verification

Verification

Hint: After carrying out the repair, check that the fault has been remedied.








- Ignition off
- Reconnect the connectors, reinstall components etc.
- Test drive the car and perform a TRIP schedule: Verifying repairs Verifying Repairs
- Connect VCT2000 to the data link connector (DLC) without switching off the engine.

Note! If the engine is switched off, the stored fault status will be erased and the test drive will have to be repeated.

Read off the dynamic for the front heated oxygen sensor (HO2S).
The value should be higher than 1.0.





Is the value OK?

Yes - VERIFIED

No - VERIFICATION FAILED

------------------------

VERIFICATION FAILED - Fault-tracing information

VERIFIED - Fault Found

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.

Do you want to exit fault-tracing?

Yes - FAULT-TRACING FAILED

No - Attempt New Test

------------------------

FAULT-TRACING FAILED - FAULT-TRACING FAILED

Attempt New Test - Checking components and wiring

-------------------------------------------------