FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Faulty Signal






Faulty signal

Checking faults




- Ignition on.
Press the power window switch 2 steps up to check the function of the automatic power window mechanism.

Is the automatic power window mechanism functioning?

Yes - Intermittent fault

No - Checking the connectors

-------------------------------------------------

Checking the connectors








- Ignition off
- Check the power window lift motor connector. Check for contact resistance and oxidation. Check for damage carefully
- Reinstall the components, reconnect the connectors etc.
- Ignition on.
Press the power window switch 2 steps up and down.

Other information:
- Window lift mechanism front side door, replacing Window Lift Mechanism Front Side Door, Replacing
- Checking wiring and terminals Checking Wiring And Terminals





Is the automatic power window mechanism functioning?

Yes - Fault Found

No - Checking for open-circuits and short-circuits

-------------------------------------------------

Checking for open-circuits and short-circuits

S80
Check the cable between control module terminal #24A and power window motor connector terminal #2. Check for a short-circuit to ground. Check for a short-circuit to supply voltage. Check for an open-circuit.
When raising or lowering the window, the voltage between power window lift motor terminal #2 and ground must be 2.4 V

S60, V70, XC70 and XC90
Check the cable between control module terminal #24A and power window lift motor terminal #5. Check for a short-circuit to ground. Check for a short-circuit to supply voltage. Check for an open circuit.
When raising or lowering the window, the voltage between power window lift motor terminal #5 and ground must be 2.4 V.
Remedy as necessary.

Other information:
- Connecting the breakout box Connecting the Breakout Box
- Signal specification Pinout Values and Diagnostic Parameters
- Checking wiring and terminals Checking Wiring And Terminals





Was a fault detected?

Yes - Verification

No - Replacing the component

-------------------------------------------------

Replacing the component




Replace the window lift mechanism.
- Ignition on.
Move the window to its upper limit position using manual control.
Initialize the window.
During initialization, the window will automatically go down to its lowest position and then go back up again.

Other information
- Window lift mechanism front side door, replacing Window Lift Mechanism Front Side Door, Replacing






Continue - Verification

-------------------------------------------------

Verification




Verification

Verification

Hint: After the repair it is necessary to check that the fault has been rectified.








- Ignition off.
- Connect connectors, install components, etc.
- Ignition on.
Check that the automatic window operation works by pressing in the button 2 stages one way or the other.

Does the automatic window operation work?

Yes - VERIFIED

No - VERIFICATION FAILED

------------------------

VERIFIED - Fault Found

VERIFICATION FAILED - Fault-tracing information

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.

Do you want to exit fault-tracing?

Yes - FAULT-TRACING FAILED

No - Attempt New Test

------------------------

Attempt New Test - Checking faults

FAULT-TRACING FAILED - No Fault Found

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).

Do you want to view the information again?

Yes - Attempt New Test

No - Fault Found

------------------------

Attempt New Test - Checking faults

FAULT FOUND - Fault Found

-------------------------------------------------

Intermittent fault
Check the connectors for the control module and power window lift motor. Check for contact resistance and oxidation. Check for loose connections.

S80
Check the cable between control module terminal #24A and power window motor terminal #2. Check for an intermittent short-circuit to ground. Check for an intermittent short-circuit to supply voltage. Check for an intermittent open-circuit.
When raising or lowering the window, the voltage between power window lift motor terminal #2 and ground must be 2.4 V

S60, V70, XC70 and XC90
Check the cable between control module terminal #24A and power window lift motor terminal #5. Check for a short-circuit to ground. Check for a short-circuit to supply voltage. Check for an open circuit.
When raising or lowering the window, the voltage between power window lift motor terminal #5 and ground must be 2.4 V.

Other information:
- Connecting the breakout box Connecting the Breakout Box
- Signal specification Pinout Values and Diagnostic Parameters
- Window lift mechanism front side door, replacing Window Lift Mechanism Front Side Door, Replacing
- Checking wiring and terminals Checking Wiring And Terminals






Continue - Fault-tracing information

-------------------------------------------------