Signal Too High






Signal too high

Checking the wiring
If the fault is intermittent, it has been registered previously but is no longer present. Intermittent faults can be caused by interference at start up or can be a different type of fault which occurs on different occasions. The fault is evaluated depending on how it occurs.
Check the fuse for the washer motor, replace if necessary.
For further information about the fuses and relays, see the Wiring Diagram
Check the cable between the central electronic module (CEM) and the washer motor. Check for a short-circuit to supply voltage.
Take readings between:
- Central electronic module (CEM) terminal #B29 (#29) and washer motor terminal #2.
Replace the central electronic module (CEM) if no fault is found.

Other information:
- Connecting the breakout box Connecting the Breakout Box, Central Electronic Module (CEM)
- Signal specification Pinout Values and Diagnostic Parameters
- Central electronic module (CEM), replacing Central Electronic Module (CEM), Replacing
- Checking wiring and terminals Checking Wiring And Terminals


Continue - Verification

-------------------------------------------------

Verification




Verification

Verification

Hint: After carrying out the repair, check that the fault has been remedied.








- Ignition off
- Reinstall the connectors, components etc.
- Ignition on.
Activate the washer motor.

Is the washer working?

Yes - VERIFIED

No - VERIFICATION FAILED

------------------------

VERIFIED - Fault Found

VERIFICATION FAILED - Fault-tracing information

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.

Do you want to exit fault-tracing?

Yes - FAULT-TRACING FAILED

No - Attempt New Test

------------------------

FAULT-TRACING FAILED - No Fault Found

Attempt New Test - Checking the wiring

-------------------------------------------------