Faulty Signal
Faulty signal
Checking the component
- Ignition on.
Check that the back-up (reversing) lamp is only lit when back-up (reverse) gear is engaged.
Was a fault detected?
Yes - Checking components and wiring
No - Checking components and wiring
-------------------------------------------------
Checking components and wiring
Check the cable between the central electronic module (CEM) and the back-up (reversing) lamp switch. Check for an open-circuit. Check for a short-circuit to ground.
Take readings between:
- Central electronic module (CEM) terminal #C34 (34) and back-up (reversing) lamp switch terminal #1 (3/10).
Measure the resistance between back-up (reversing) lamp switch terminals #1 and #2 with gears 1 to 5 engaged. The resistance must be high.
Hint: The back-up (reverse) gear switch should be open in all gear positions except back-up (reverse).
Remedy as necessary.
Other information
- Connecting the breakout box Connecting the Breakout Box, Central Electronic Module (CEM)
- Signal specification Pinout Values and Diagnostic Parameters
- Back-up lamp switch, replacing Service and Repair
- Checking wiring and terminals Checking Wiring And Terminals
Continue - Verification
-------------------------------------------------
Verification
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on.
The back-up (reversing) lamp should not light with gears 1 to 5 engaged.
Is the function OK?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFIED - Fault Found
VERIFICATION FAILED - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - FAULT-TRACING FAILED
Attempt New Test - Checking the component
-------------------------------------------------
Checking components and wiring
Check central electronic module (CEM) connector C. Check for contact resistance and oxidation. Check for damage in particular.
Check the connector on the back-up (reversing) lamp switch. Check for contact resistance and oxidation. Check for damage in particular.
Check the cable between the central electronic module (CEM) and the back-up (reversing) lamp switch. Check for an open-circuit. Check for an intermittent short-circuit to ground.
Take readings between:
- Central electronic module (CEM) terminal #C34 (34) and back-up (reversing) lamp switch terminal #1 (3/10).
Other information
- Connecting the breakout box Connecting the Breakout Box, Central Electronic Module (CEM)
- Signal specification Pinout Values and Diagnostic Parameters
- Back-up lamp switch, replacing Service and Repair
- Checking wiring and terminals Checking Wiring And Terminals
Continue - Verification
-------------------------------------------------