Short-circuit to Ground
Short-circuit to ground
Checking the wiring
- Ignition off
- Disconnect central electronic module (CEM) connector D.
Check the signal cable. Check for a short-circuit to ground.
Take readings between:
- Central electronic module (CEM) terminal #D44 (44) and the fuel level sensor on the right-hand side.
Remedy as necessary.
Other information
- Connecting the breakout box Connecting the Breakout Box, Central Electronic Module (CEM)
- Signal specification Pinout Values and Diagnostic Parameters
- Central electronic module (CEM), replacing Central Electronic Module (CEM), Replacing
- Level sensor fuel tank, replacing Service and Repair
- Checking wiring and terminals Checking Wiring And Terminals
Continue - Verification
-------------------------------------------------
Verification
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on.
Check if the value at the fuel level gauge changes.
Is the value within its permitted range?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFIED - Fault Found
VERIFICATION FAILED - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - FAULT-TRACING FAILED
Attempt New Test - Checking the wiring
-------------------------------------------------