Faulty Signal
Faulty signal
Replacing the component
The fault has probably occurred as a result of a defective potentiometer or a short-circuit in the potentiometer. If the fault is intermittent, it has been registered previously but is no longer present. Intermittent faults may be caused by interference at start up of the control module. Intermittent faults may also be caused by other types of intermittent faults. The fault is evaluated depending on how it occurs. If the fault recurs, replace the control module.
If the fault persists, replace the climate control module (CCM). The potentiometer cannot be replaced as a separate part.
Other information:
- To access and replace the control module, see Climate control module (CCM), replacing Service and Repair.
Select "Continue" when the fault has been remedied.
Continue - Checking LIN bus
-------------------------------------------------
Checking LIN bus
Identification
Hint: After replacing the climate control module (CCM), the LIN bus must be checked to identify which damper motors are installed and to identify their function and positions.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on.
Click the VCT2000 symbol to activate the check.
Continue - DONE
------------------------
DONE - Verification
-------------------------------------------------
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on
- Blower fan on.
Check the function of the temperature control. Turn the control between the minimum and maximum positions.
A the same time, check the desired and actual position of the damper motors during control. Ensure that the desired and actual positions are approximately the same.
The values listed below should be seen as guidelines for the positions which the damper motors should reach.
Note! The blower fan must be running for the damper motors to be activated.
- Temperature damper motor left/right 0-100%
- Recirculation damper motor, 40-100%
- Air distribution damper motor, defroster approximately 0%, floor/defroster approximately 19%, floor approximately 39%, vent approximately 83%.
Is the damper motor functioning?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFICATION FAILED - Information
VERIFIED - Fault Found
-------------------------------------------------
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
Attempt New Test - Replacing the component
FAULT-TRACING FAILED - No Fault Found
-------------------------------------------------