Connecting the Breakout Box, Convertible Roof Module (CRM)
Connecting the breakout box
Special tools:
951 2978 CRM adapter 951 2978 CRM Adapter
951 1428 Breakout box 951 1428 Breakout Box
951 1499 Cable 951 1499 Cable
Connecting the breakout box
- Ignition off
- Remove the fuse.
- Expose the Convertible Roof Module (CRM).
- Disconnect all the control module connectors.
Connect adapter 951 2978 CRM adapter 951 2978 CRM Adapter to all the control module connectors and connect breakout box 951 1428 Breakout box 951 1428 Breakout Box and wiring 951 1499 Cable 951 1499 Cable to the adapter.
Then connect the control module connector to 951 2978 CRM adapter 951 2978 CRM Adapter.
Disconnect the breakout box in reverse order.
Other information:
- Signal specification Signal Specification, Convertible Roof Module (CRM)
- Convertible Roof Module (CRM) Removal and Replacement
- For information on fuses, see the relevant wiring diagram.