FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Internal Fault






Internal fault

Replacing a component
Convertible Roof Module (CRM) has registered an internal malfunction.
If the fault is intermittent it means that it has been registered previously but is no longer present. Intermittent faults can occur for a number of different reasons. The fault is evaluated depending on how it occurs. If the fault recurs, try downloading new software to the control module. After software downloading, the roof must be calibrated.
In the event of a permanent fault, try downloading new software to the control module. After software downloading, the roof must be calibrated.
Remedy as necessary.

Other information
- Convertible Roof Module (CRM) Removal and Replacement





Continue - Verification

-------------------------------------------------

Verification




Verification

Hint: After carrying out the repair, check that the fault has been remedied.








- Ignition off.
- Reinstall the connectors, components etc.
- Ignition on.
Check the function of the convertible roof module (CRM) by operating the roof with the control buttons.





Does operation of the roof work?

Yes - FAULT FOUND

No - No Fault Found

------------------------

No Fault Found - Fault-tracing information

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.

Do you want to exit fault-tracing?

Yes - Exit Fault-Tracing

No - Attempt New Test

------------------------

Attempt New Test - Replacing a component

-------------------------------------------------