Faulty Signal
Faulty signal
Checking the status
- Ignition on.
Activate the stop lamp.
Check if the fault is permanent or intermittent.
The stop lamp must light on activation.
The fault is permanent if the stop lamp does not activate.
If the stop lamp is activated, this is an indication that the fault was present previously but that it is not active at the moment, i.e. the fault is intermittent.
Continue - Checking the component and wiring
-------------------------------------------------
Checking the component and wiring
5-doors
Check the voltage on the right-hand stop lamp connector terminal #2 to the output on the central electronic module (CEM). The voltage must be approximately 12 V when the stop lamp is activated.
Check the control signal cable. Check for an open-circuit. Check for a short-circuit to supply voltage.
Take readings between:
- Central electronic module (CEM) terminal #C4 (#4) and right-hand stop lamp connector terminal #1.
Remedy as necessary.
4-doors
Check the voltage on the right-hand stop lamp connector terminal #3 to the output on the central electronic module (CEM). The voltage must be approximately 12 V when the stop lamp is activated.
Check the control signal cable. Check for an open-circuit. Check for a short-circuit to supply voltage.
Take readings between:
- Central electronic module (CEM) terminal #C4 (#4) and right-hand stop lamp connector terminal #3.
Remedy as necessary.
Other information
- Connecting the breakout box Connecting the Breakout Box, Central Electronic Module (CEM)
- Signal specification Signal Description, Central Electronic Module (CEM)
- Control module relay box passenger compartment Service and Repair
- Checking wiring and terminals Checking Wiring and Terminals
Continue - Verification
-------------------------------------------------
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on.
Click the VCT2000 symbol to activate and deactivate the right-hand stop lamp.
Check that the function is OK.
Is the function OK?
Yes - Troubleshooting procedure complete
No - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit Fault-Tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking the component and wiring
-------------------------------------------------