Signal Too High / Signal Missing
Signal too high / Signal missing
Checking the component and wiring
Check the signal cable for the alarm output S1. Check between accessory electronic module (AEM) terminal #B34 and the connector for the alarm unit. Check for a short-circuit to supply voltage. Check for an open-circuit.
Remedy as necessary.
Other information:
- Connecting the breakout box Connecting the Breakout Box, Accessory Electronic Module (AEM)
- Accessory control module (AEM) Accessory Control Module (AEM)
- Signal specification Signal Description, Accessory Electronic Module (AEM)
- Checking wiring and terminals Checking Wiring and Terminals
Continue - Verification
-------------------------------------------------
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reconnect the components, connectors etc.
- Ignition on.
Check the function of the alarm by activating it appropriately.
Does the system function?
Yes - Troubleshooting procedure complete
No - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit Fault-Tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking the component and wiring
-------------------------------------------------