Signal Too High
Signal too high. Intermittent fault
Intermittent fault
- Ignition off.
Warning! Never use an ohmmeter or any other charged measuring instrument on a disconnected, undeployed explosive inflatable curtain. There is a risk that the inflatable curtain could be deployed!
Caution! Avoid touching the contact pins in the supplemental restraint system (SRS) control unit. There is a risk of an electrostatic discharge which can cause damage to the supplemental restraint system (SRS) control unit.
Check the supplemental restraint system (SRS) control unit connector and the inflatable curtain connector for contact resistance and oxidation as described in Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults and for a loose contact as described in Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Check the wire between the supplemental restraint system (SRS) control unit 21A (21), 22A (22) and connector 1, 3 on the left inflatable curtain for an intermittent short circuit to voltage supply as described in Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Do the necessary corrective action.
Additional information:
- To access/replace SRS control unit connector, Service and Repair.
- To access/replace the left inflatable curtain connector, see IC (inflatable curtain) module, replacing IC (Inflatable Curtain) Module, Replacing
- To connect the test box, see Connecting the breakout box Connecting the Breakout Box, Supplemental Restraint System Module (SRS)
- With ignition off and the left inflatable curtain connector disconnected and SRS control unit connector disconnected, the resistance between the inflatable curtain connector 1, 3 (to the supplemental restraint system (SRS) control unit) and the disconnected battery connection should be infinite
- For more information on removal of battery cables, see Battery, disconnecting Battery Disconnecting
- For information on repairing the SRS wiring, see Cable harness SRS system, repair Procedures
- For additional values, see Signal specification Signal Description, Supplemental Restraint System (SRS) Control Unit.
Continue - Trouble-shooting information
-------------------------------------------------
Trouble-shooting information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Exit fault-tracing
------------------------
Attempt New Test - Intermittent fault
-------------------------------------------------