Signal Too Low. Permanent Fault
Signal too low. Permanent fault
Checking wiring and connectors
Check the resistance of the fuel level sensor (right-hand side). The resistance across each sensor may vary between 12 ohms (full fuel tank) and 383 ohms (empty fuel tank).
Hint: The resistance of the right-hand side fuel level sensor can be measured between fuel level sensor connector terminals #7 and #6. The resistance of the left-hand side fuel level sensor can be measured between fuel level sensor connector terminals #5 and #6.
Check the cables between connector terminal #7 on the fuel level sensors and control module terminal #A08 (#A8). Check for a short-circuit to ground. Check for an open-circuit.
Check the ground lead between control module terminal #A10 (#A10) and fuel level sensor connector terminal #6. Check for an open-circuit.
Check the cables between the left and right fuel level sensors. Check for an open-circuit.
Remedy as necessary.
Other information:
- For further information about signals and other values, see Signal specification Pinout Values and Diagnostic Parameters
- To connect the breakout box, see Connecting the breakout box Connecting Breakout Box, Rear Electronic Module (REM)
- To access the control module, see Integrated relay/fuse box cargo compartment/rear electronic module, replacing Integrated Relay/Fusebox Cargo Compartment/Rear Electronic Module (REM), Replacing
- To access the fuel level sensors, see Left fuel gauge sensor Left Fuel Gauge Sensor and Right side fuel pump with level sensor Right Side Fuel Pump With Level Sensor
- Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Continue - Verification
-------------------------------------------------
Verification
Verification
Verification
Hint: After the repair it is necessary to check that the fault has been rectified.
- Ignition off.
- Install the components, connect the connectors, etc.
- Make sure there are more than two litres of fuel in the right tank half.
- Ignition on.
Read the fuel level in the right tank half.
Is the value normal?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFIED - Fault Found
VERIFICATION FAILED - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
Attempt New Test - Checking wiring and connectors
FAULT-TRACING FAILED - No Fault Found
-------------------------------------------------