Signal Too High. Intermittent Fault
Intermittent Fault
Check the wiring between transmission control module (TCM) terminal #2 and terminal #3 on the 8-pin transmission connector. Check the wiring between control module terminal #30 and terminal #4 on the 8-pin transmission connector. Check for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults.
HINT: Check the solenoid SLT by measuring the resistance between terminals #3 and #4 on the transmission connector. The ohmmeter should be 5 - 6 Ohms at 20 degree C.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box.
- To disconnect the transmission connectors, see Replacing the Transmission control module (TCM).
- To disconnect the transmission connector, see Transmission connectors.
- For information about signals, see Signal description. Transmission control module (TCM).
Select Continue when the fault has been remedied.
Continue with Next Procedure. Fault-Tracing Information - Intermittent Fault