Signal Too Low. Intermittent Fault - I
Intermittent Fault
Check the transmission control module (TCM) and transmission connectors for contact resistance and oxidation according Checking wiring and terminals. Intermittent faults.
Check the transmission control module (TCM) terminal #4 and terminal #5 on the 8-pin transmission connector. Check the wiring between control module terminal #32 and terminal #6 on the 8-pin transmission connector. Check for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults.
HINT: Check the solenoid SLS by measuring the resistance between #5 and #6 on the transmission connector. The ohmmeter should read 5 - 5.6 Ohms at 20 degree C.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box.
- To disconnect the transmission control module (TCM), see Replacing the Transmission control module (TCM).
- To disconnect the transmission connector, see Transmission connectors.
- For information about signals, see Signal description. Transmission control module (TCM).
Select Continue when the fault has been remedied.
Continue with Next Procedure. Fault-Tracing Information - Intermittent Fault