Signal Too High. Intermittent Fault
Intermittent Fault
Check the wiring between transmission control module (TCM) terminal #3 and terminal #1 on the 8-pin transmission connector. Check the wiring between control module #31 and transmission connector terminal #2. Check for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box.
- To disconnect the transmission connector, see Transmission connectors.
- For information about signals, see Signal description. Transmission control module (TCM).
Select Continue when the fault has been remedied.
Continue with Next Procedure. Fault-Tracing Information - Intermittent Fault