Faulty Signal
Faulty signal
Replacing the component
If the fault is intermittent, it has been registered previously but is no longer present. Intermittent faults can occur for a number of different reasons. The fault is evaluated depending on how it occurs.
Replace the power seat module (PSM) in the event of a permanent fault.
Remedy as necessary.
Other information:
- Control module front seat Service and Repair Control module front seat Service and Repair.
Continue - Verification
-------------------------------------------------
Verification
Verification seat operation
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on.
Check that seat operation functions. Move the seat manually in all directions.
Does the seat operation function?
Yes - Fault Found
No - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
-------------------------------------------------