Signal Too Low. Intermittent Fault
Signal too low. Intermittent fault
Checking the wiring
Check the signal cable between control module terminal #B44 and air conditioning (A/C) relay terminal #4. Check for an intermittent short-circuit to ground.
Other information
- To connect the breakout box / access the control module, see Connecting the breakout box, B5234T9, B5244T7 Connecting The Breakout Box
- For further information about the fuses and relays, see the Wiring Diagram
- For information about signals on 5 cylinder engines, see Signal specification Signal Specifications
- For information about signals on 6 cylinder engines, see Signal specification Signal Specifications
- Checking wiring and terminals Checking Wiring and Terminals.
Continue - Fault-tracing information
DONE
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Checking the wiring