Signal Missing. Intermittent Fault
Signal missing. Intermittent fault
Checking wiring and connectors
Check the injector connector. Check for contact resistance and oxidation. Check for loose connections.
Check the cable between injector terminal 2 and control module:
- terminal #A16 (#A16) (ECM 2310)
- terminal #A34 (#A34) (ECM 2320)
- terminal #A15 (#A15) (ECM 2330)
- terminal #A33(#A33) (ECM 2340)
- terminal #A14 (#A14) (ECM 2350).
Check the power supply between system relay terminal 3 and injector terminal 1. Check for an for an intermittent open-circuit.
Other information
- To connect the breakout box / access the control module, see Connecting the breakout box, B5234T9, B5244T7 Connecting The Breakout Box
- To access or replace the injector, see Injectors/pulsation dampers, replacing Removal and Replacement
- For information about signals, see Signal specification Signal Specifications
- Checking wiring and terminals Checking Wiring and Terminals.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
Attempt New Test - Checking wiring and connectors
FAULT FOUND - DONE
-------------------------------------------------