Check Hazard Warning Signal Flasher and Glove Compartment Lighting
Check hazard warning signal flasher and glove compartment lighting
Checking the cable
- Ignition off.
Check the cable between the central electronic module (CEM) terminal #17D and the hazard warning signal flasher switch terminal #1 (3/6). Check for a short-circuit to supply voltage. Check for an open-circuit.
Remedy as necessary.
If no faults were found, replace the switch.
Other information:
- For information about the central electronic module (CEM) connector, see Central electronic module (CEM), replacing Central Electronic Module (CEM), Replacing
- To connect the breakout box, see Connecting the breakout box Connecting the Breakout Box, Central Electronic Module (CEM)
- For information about signals, see Signal specification Pinout Values and Diagnostic Parameters
- To replace the switch for the hazard warning signal flasher, see Switch hazard warning signal flasher, replacing Switch, Hazard Warning Signal Flasher, Replacing
- Checking wiring and terminals Checking Wiring And Terminals.
Is the function OK?
Yes - Fault Found
No - No Fault Found
-------------------------------------------------