Signal Too High
Signal too high
Checking and replacing the component
Replace the relay, 2/115.
Activate the relay.
If the function is OK, the cause of the fault was a defective relay (short-circuit in the relay).
Other information:
- To access the integrated relay / fusebox in the cargo compartment, see Integrated relay / fusebox cargo compartment / rear electronic module, replacing Integrated Relay/Fusebox Cargo Compartment/Rear Electronic Module (REM), Replacing.
Was the function OK?
Yes - Fault Found
No - Checking the control module
-------------------------------------------------
Checking the control module
- Remove the relay.
Check the relay coil driver circuit for a short-circuit to supply voltage by measuring the voltage at terminal #2 in the relay base.
Hint: The voltage between terminal #2 and ground should be approximately 0 V.
Replace the control module if the voltmeter displays an incorrect value.
Other information:
- To access and replace the integrated relay / fusebox in the cargo compartment, see Relay/fuse box cargo compartment/Rear electronic module (REM), replacing Integrated Relay/Fusebox Cargo Compartment/Rear Electronic Module (REM), Replacing
- Checking wiring and terminals Checking Wiring And Terminals.
Continue - Verification
-------------------------------------------------
Verification
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on.
Activate the relay.
Was the function OK?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFIED - Fault Found
VERIFICATION FAILED - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
Attempt New Test - Checking and replacing the component
FAULT-TRACING FAILED - No Fault Found
-------------------------------------------------