Signal Too High
Signal too high
Checking the connectors and components
Check the charging function of the generator (GEN). Check for high charging voltage.
Remedy as necessary.
Other information
- To fault-trace the charging system, see Fault-tracing and testing the voltage supply system Component Tests and General Diagnostics.
Continue - Verification
-------------------------------------------------
Verification
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Start the engine
- Read off the voltage from the system relay to the engine control module (ECM).
Check that the voltage is correct. The voltage must be approximately 12 V.
Is the voltage correct?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFICATION FAILED - Fault-tracing information
VERIFIED - Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - FAULT-TRACING FAILED
Attempt New Test - Checking the connectors and components
-------------------------------------------------