Signal Too Low - Intermittent Fault
Signal too low. Intermittent fault
Checking cables
Check signal cable between control module #A47 (#A47) and camshaft position (CMP) sensor connector #2 for an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults. Check power cable between control module #A29 (#A29) and camshaft position (CMP) sensor connector #1 for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults
Other information
- Connecting the breakout box/accessing the control module, see Connecting the breakout box, B5244T5, B5254T2 Connecting the Breakout Box.
- For component location on the B52X4 T see Location of components Locations.
- For component location on the B6304 S see Location of components Locations.
- For component location on the B6284 T see Location of components Locations.
- For information about signals, see Signal specification Signal Description / Specification.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Fault Found
------------------------
Attempt New Test - Checking cables
FAULT FOUND - DONE
-------------------------------------------------