Signal Missing - Intermittent Fault
Signal missing. Intermittent fault
Checking wiring and connectors
Check the heated oxygen sensor (HO2S) connector. Check for contact resistance and oxidation. Check for loose connections.
Check the signal cable between heated oxygen sensor (HO2S) terminal #4 and control module terminal #A18 (#A18). Check the power supply between system relay terminal #3 and heated oxygen sensor (HO2S) terminal #3. Check for an intermittent open-circuit.
Other information
- To connect the breakout box / access the control module, see Connecting the breakout box, B5244T5, B5254T2 Connecting the Breakout Box
- To access or replace the heated oxygen sensor (HO2S), see Heated oxygen sensor (HO2S), replacing Heated Oxygen Sensor (HO2S), Replacing
- For information about signals on 5 cylinder engines, see Signal specification Signal Description / Specification
- For information about signals on 6 cylinder engines, see Signal specification Signal Description / Specification
- Checking wiring and terminals Checking Wiring And Terminals.
Continue - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Fault Found
------------------------
Attempt New Test - Checking wiring and connectors
FAULT FOUND - DONE
-------------------------------------------------