FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Faulty Signal - Intermittent Fault






Faulty signal. Intermittent fault

Checking connectors and wiring

Caution! Do not apply rust solvent spray or grease to the heated oxygen sensor (HO2S) connector.

Check the heated oxygen sensor (HO2S) connector. Check for contact resistance and oxidation. Check for loose connections.
Check the signal cable (+) between heated oxygen sensor (HO2S) terminal #1 and control module terminal #A41 (#A41). Check the signal cable (-) between heated oxygen sensor (HO2S) terminal #5 and the control module terminal #A42 (#A42). Check the cable for calibration current between heated oxygen sensor (HO2S) terminal #2 and control module terminal #A28 (#A28). Check the cable for pump current between heated oxygen sensor (HO2S) terminal #6 and control module terminal #A24 (#A24). Check for an intermittent short-circuit to supply voltage.
Check the signal cable (+) between heated oxygen sensor (HO2S) terminal #1 and control module terminal #A41 (#A41). Check the signal cable (-) between heated oxygen sensor (HO2S) terminal #5 and control module terminal #A42 (#A42). Check the cable for calibration current between heated oxygen sensor (HO2S) terminal #2 and the control module terminal #A28 (#A28). Check the cable for pump current between heated oxygen sensor (HO2S) terminal #6 and control module terminal #A24 (#A24). Check for an intermittent short-circuit to ground.
Check the signal cable (+) between heated oxygen sensor (HO2S) terminal #1 and control module terminal #A41 (#A41). Check for an intermittent open-circuit.

Other information
- To connect the breakout box / access the control module, see Connecting the breakout box, B5244T5, B5254T2 Connecting the Breakout Box
- To access or replace the heated oxygen sensor (HO2S) for the C70, S70, V70 -2000 and V70XC, see Adapter wiring switch, replacing Adapter Wiring Switch, Replacing. For other models, see Heated oxygen sensor (HO2S), replacing Heated Oxygen Sensor (HO2S), Replacing
- For information about signals on 5 cylinder engines, see Signal specification Signal Description / Specification
- For information about signals on 6 cylinder engines, see Signal specification Signal Description / Specification
- Checking wiring and terminals Checking Wiring And Terminals.














Continue - Fault-tracing information

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).

Do you want to view the information again?

Yes - Attempt New Test

No - Fault Found

------------------------

Attempt New Test - Checking connectors and wiring

FAULT FOUND - DONE

-------------------------------------------------