Signal Too Low. Intermittent Fault
Signal too low. Intermittent fault
Checking the wires and contacts
Check wiring between central electronic module (CEM) #9A and beam setting control #2 (6/38) for LH and (6/39) for RH actuator, for an intermittent short circuit to ground, as described in Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Also check wiring between central electronic module (CEM) #8A and beam setting control #3 (6/38) for LH and (6/39) for RH actuator an for intermittent open circuit, as described in Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Do the necessary corrective action
Additional information:
- For information on the central electronic module (CEM), see Central electronic module (CEM), replacing Central Electronic Module (CEM), Replacing.
Continue - Trouble-shooting information
-------------------------------------------------
Trouble-shooting information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Fault Found
------------------------
Attempt New Test - Checking the wires and contacts
FAULT FOUND - DONE
-------------------------------------------------