Faulty Signal
Faulty signal
Checking the function of the combustion fan
- Ignition on
- Activate the combustion fan.
Listen for a buzzing sound which indicates that the combustion fan is running.
Does the combustion fan function?
Yes - Intermittent fault
No - Checking the connectors
-------------------------------------------------
Checking the connectors
- Ignition off
- Check the electrical terminals on the combustion fan and the control module connector. Check for contact resistance and oxidation and remedy.
Check for damage carefully
- Reinstall the components, reconnect the connectors etc.
- Ignition on
- Activate the combustion fan.
Listen for a buzzing sound which indicates that the combustion fan is running.
If the combustion fan now operates, the cause of the fault was loose connections in the connectors.
Other information:
- To access the control module or connect the breakout box, see Connecting the breakout box Connecting the Breakout Box
- To access the combustion fan, see Fuel injection nozzle / fan motor / pressure equalizer, replacing Fuel Injection Nozzle / Fan Motor / Pressure Equalizer, Replacing
- Checking wiring and terminals Checking Wiring And Terminals.
Does the combustion fan function?
Yes - Fault Found
No - Replacing the component
-------------------------------------------------
Replacing the component
- Ignition off.
Try a new combustion fan. See Fuel injection nozzle / fan motor / pressure equalizer, replacing Fuel Injection Nozzle / Fan Motor / Pressure Equalizer, Replacing.
Continue - Verification
-------------------------------------------------
Verification
Verification
Verification
Hint: After the repair it is necessary to check that the fault has been rectified.
- Ignition off.
- Connect connector, install components etc.
- Ignition on.
- Activate the heater fan.
Listen for a buzzing sound indicating that the heater fan is working.
Is the heater fan working?
Yes - VERIFIED
No - VERIFICATION FAILEDPAPER
------------------------
VERIFICATION FAILED - Fault-tracing information
VERIFIED - Fault Found
PAPER - No Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - FAULT-TRACING FAILED
Attempt New Test - Checking the function of the combustion fan
-------------------------------------------------
Intermittent fault
- Ignition off.
Check the electrical terminals on the combustion fan and the control module connector. Check for contact resistance and oxidation.
Other information:
- To access the control module or connect the breakout box, see Connecting the breakout box Connecting the Breakout Box
- To access the combustion fan, see Fuel injection nozzle / fan motor / pressure equalizer, replacing Fuel Injection Nozzle / Fan Motor / Pressure Equalizer, Replacing
- Checking wiring and terminals Checking Wiring And Terminals.
Continue - Fault-tracing information
DONE
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Fault Found
------------------------
Attempt New Test - Checking the function of the combustion fan
DONE - DONE
FAULT FOUND - Fault Found
-------------------------------------------------