Signal Too High. Intermittent Fault
Signal too high. Intermittent fault
Intermittent fault
- Ignition off.
Check the signal lead between:
- between central electronic module (CEM) 14C and fuel pump relay 2/23 1 (large illustration) and fuel pump 1 (small illustration).
for a short circuit to voltage supply as described in Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Do the necessary corrective action.
Additional information:
- To access/replace the central electronic module (CEM), see Central electronic module (CEM), replacing Central Electronic Module (CEM), Replacing
- To connect a test box, see Connecting the breakout box Connecting the Breakout Box, Central Electronic Module (CEM)
- For information on signals, see Signal specification Pinout Values and Diagnostic Parameters.
Continue - Trouble-shooting information
-------------------------------------------------
Trouble-shooting information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - Fault Found
------------------------
Attempt New Test - Intermittent fault
FAULT FOUND - DONE
DONE - DONE
-------------------------------------------------