Signal Too High. Permanent Fault
Signal too high. Permanent fault
Checking the relay
- Ignition off.
Check that relay 2/29 is installed correctly. At the same time check relay connection for contact resistance and oxidation as described in Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
Additional information
- For interior relay unit, see Central electronic module (CEM), replacing Central Electronic Module (CEM), Replacing
Is there a fault?
Yes - Verification
No - Replacing the component
-------------------------------------------------
Replacing the component
Replace the relay.
Additional information
- For interior relay unit, see Central electronic module (CEM), replacing Central Electronic Module (CEM), Replacing
Continue - Verification
-------------------------------------------------
Verification
Verification
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on.
Click on the VCT2000 symbol. To activate and deactivate the relay, click a number of times on "Start activation" and "End activation" for the current function.
Did the relay click?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFIED - Fault Found
VERIFICATION FAILED - Trouble-shooting information
-------------------------------------------------
Trouble-shooting information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - No Fault Found
Attempt New Test - Checking the relay
-------------------------------------------------