UEM-000B
Condition
If the upper electronic module registers too low a signal for the mass movement sensor supply wire when the alarm is set, diagnostic trouble code UEM-000B is displayed.
Substitute value
- Nothing.
Possible source
- Sensor power supply short circuited to ground.
- Faulty sensor.
Fault symptom[s]
- No alarm from sensor.