SRS-00BF
Condition
If the circuit voltage is high or low for more than 10 seconds, diagnostic trouble code SRS-00BF is displayed.
Substitute value
- Nothing.
Possible source
Signal too high:
- Signal wire short circuited to voltage supply.
- Faulty side impact sensor.
Signal too low:
- Signal wire short circuited to ground.
- Faulty side impact sensor.
Fault symptom[s]
- SRS warning lamp on.