SRS-0072
Condition
If the circuit capacitance is too high for more than 10 seconds, diagnostic trouble code SRS-0072 is displayed.
Substitute value
- Nothing.
Possible source
- Capacitance too high in connector.
- Capacitance too high in the signal wire between seat-belt tensioner and the supplemental restrain system (SRS).
Fault symptom[s]
- Orange general warning lamp is on.