SRS-0042
Condition
If the circuit capacitance is too high for more than 10 seconds, diagnostic trouble code SRS-0042 is displayed.
Substitute value
- Nothing.
Possible source
- Capacitance too high or short circuit in built-in capacitor in igniter wire connector.
Fault symptom[s]
- SRS warning lamp on.