SRS-0011
Condition
If the control unit registers that the voltage in the circuit is low (0 V) for more than 10 seconds, diagnostic trouble code SRS-0011 is displayed.
Substitute value
- Nothing.
Possible source
- Short circuit to ground in igniter wire or in the connectors between the air bag and the supplemental restraint system.
- (SRS) control unit.
- Short circuit to ground in air bag.
- Short circuit to ground in contact reel.
Fault symptom[s]
- SRS warning lamp on.